Redefining Lightweight Excellence in Spectrum Analysis, State-of-the-art monitoring receiver weighing just 900g
Features

Receiver mode
Real-time bandwidth 15MHz max, waterfall graph and digital phosphor display. Multiple demodulation mode and IQ record.

Source mode
Full frequency rang support, 90dB setting range of output level, AF/FM/PM modulation and IQ replay.

Spectrum mode
3GHz/s fast sweep, zero to full span sweeping, configurable RBW, storing a list of signals of interest.

Correlator mode
Compares the phase and amplitude of the two channels and displays the difference.
Highlights
- Better than 15KHz frequency measurement accuracy with any sweep span
Receiver Mode

DMR/P25/Tetra and more... Now demodulated monitoring in one device
Built-in multiple vocoders to support a variety of digital voice combinations
Demodulation by makers, for fast multi-signal monitoring

Waterfall and digital phosphor display for hidden signal identification

Multiple squelch methods, including CTS/DCS and analysis

Level tone for direction finding and signal search

Read frequency list form spectrum mode wide range sweep
Spectrum Mode

Performing spectrum analysis functions will not need tonnes of instruments. KC908 scanning up to 18.6 GHz range, automatic RBW for highly accurate frequency results at any span. Peak list function automatically records the frequency and POI of signals that occur.

Extensive trace functions and configurable detector modes

Zero Span use for time domain analysis with trigger mode setting
Signal Source
RF signal output covering the entire frequency range, supporting AM/FM/PM modulation modes, 90dB amplitude setting range. Most importantly, IQ replay is supported!
Play IQ file record by KC908 or import files to Micro SD card. also can set amplitude and replay frequency. This is a useful feature for testing digital systems.
The KC908B has the most powerful signal source in the series, with a maximum output amplitude of +10dBm 18GHz and a synchronous tuning filter.
Correlator
Performance
With professional and precise hardware design, high performance is realized in a very small volume, and strict RF front-end design, even the weakest signals can be detected under the strong interference field.
KC908 has a built-in multi band Pre-filter that automatically switches to the current operating frequency.
| Item | Min value | Typical value | Max value | Note |
|---|---|---|---|---|
| Frequency range | 100kHz | 4/6/10.8/18.6GHz | ||
| Real time bandwidth | 1kHz | continuously adjustable | 15MHz | |
| Analysis bandwidth | 1Hz | continuously adjustable | 2MHz | Can be set to 8MHz |
| Demodulation bandwidth | 150Hz | continuously adjustable | 300KHz | |
| 100% POI (note 3) | 210us | SPAN=15MHz | ||
| Level measurement range | +20dBm | |||
| Level measurement uncertainty | 1.5dB | Receiver mode | ||
| Noise floor | -120dBm | @12kHz BW, avg | ||
| Normalized noise floor | -163dBm/Hz | Max Gain, avg | ||
| Instrument noise coefficient | 13dB | Max Gain | ||
| Third-order intercept pointa | -42dBm | 46dBm | REF = -70dBm | |
| First image suppression | 50dB | 70dB | REF = 20dBm | |
| IQ image suppression | 60dB | |||
| Residual response (note 4) | -110dBm | Port N.C | ||
| Spurious response | -90dBm | With Whip Antenna | ||
| Signal generator output level (note 5) | -80dBm | 10dBm | 1dB Step | |
| Battery life | 4h | |||
| Weight | 900g |