Handheld Vector Network Analyzer PNB-60 100 kHz to 6 GHz

1,423.10

Frequency Range: 100 kHz to 6 GHz
Number of Ports: 2 ports
High-performance directional coupler with effective directivity 40 dB
Output power:-35 dBm to 5 dBm
Dynamic range: 100 dB to 120 dB (typ.)
Trace noise:≤0.003 dBrms (typ.)
IF bandwidth:15 Hz to 75 kHz
Sweep speed: 150 us/point at 75 kHz IF bandwidth
Supports the ECB-60 electronic calibration module
5-hour battery life with power bank support

Category:

Description

PNB-60 product image

KEY FACTS

  • Frequency Range: 100 kHz to 6 GHz
  • Number of Ports: 2 ports
  • High-performance directional coupler with effective directivity 40 dB
  • Output power: -35 dBm to 5 dBm
  • Dynamic range: 100 dB to 120 dB (typ.)
  • Trace noise: ≤0.003 dBrms (typ.)
  • IF bandwidth: 15 Hz to 75 kHz
  • Sweep speed: 150 us/point at 75 kHz IF bandwidth
  • Supports the ECB-60 electronic calibration module
  • 5-hour battery life with power bank support

PNB-60 product showcase

Benefits

Highlight

VNB-60 is a dual-port USB vector network analyzer covering 100 kHz to 6 GHz and supporting full S-parameter measurements, including S11, S12, S21, and S22. It features high-performance directional couplers with an effective directivity of ≥40 dB, a typical dynamic range of 100–120 dB, an IF bandwidth from 15 Hz to 75 kHz, and a sweep speed of up to 150 μs per point at 75 kHz IFBW. Its 50 Ω RF ports use female SMA connectors, with an output power range of −35 dBm to +5 dBm from 10 MHz to 6 GHz. Both manual and electronic calibration are supported, including use with the ECB-60 electronic calibration module and phase-stable, amplitude-stable test cables. Together with VNStudio software, it provides sweep configuration, calibration, Smith chart, VSWR and phase displays, as well as CSV and S2P data export. It is suitable for measuring the network parameters of RF components such as filters, amplifiers, cables, and antennas.

Main Functions Overview

Clear and User-Friendly Interface

Clear and User-Friendly Interface

Two-Port S-Parameter Measurements

Two-Port S-Parameter Measurements

Flexible Sweep and Scenario Configuration

Flexible Sweep and Scenario Configuration

Automatic Search and Analysis

Automatic Search and Analysis

Specifications*

Frequency

Frequency range 100 kHz to 6 GHz
Frequency resolution ≤ 10 Hz
Reference clock Internal or external
Frequency stability < ± 2.5 ppm
Aging rate ≤1 ppm/year
Sweep points 11 to 65535
IF Bandwidth Range 15 Hz to 75 kHz

S-Parameter Measurement Capability

Dynamic range
15 Hz IF Bandwidth
100 kHz to 1 MHz 90 dB, 100 dB (typ.)
1 MHz to 10 MHz 100 dB, 105 dB (typ.)
10 MHz to 3 GHz 115 dB, 120 dB (typ.)
3 GHz to 4.5 GHz 110 dB, 115 dB (typ.)
4.5 GHz to 6 GHz 110 dB, 115 dB (typ.)
Corrected System Performance (typ.) Frequency Range 85033E Mechanical Calibration Kit ECB-60 Electronic Calibration Module
Directivity 100 kHz to 1 MHz 45 dB 32 dB
1 MHz to 10 MHz 50 dB 45 dB
10 MHz to 4.5 GHz 50 dB 48 dB
4.5 GHz to 6 GHz 44 dB 42 dB
Load match 100 kHz to 1 MHz 40 dB 30 dB
1 MHz to 10 MHz 46 dB 44 dB
10 MHz to 4.5 GHz 48 dB 46 dB
4.5 GHz to 6 GHz 44 dB 42 dB
Source match 100 kHz to 1 MHz 42 dB 25 dB
1 MHz to 10 MHz 46 dB 44 dB
10 MHz to 4.5 GHz 46 dB 38 dB
4.5 GHz to 6 GHz 42 dB 32 dB
Transmission tracking 100 kHz to 1 MHz ± 0.05 dB ± 0.15 dB
1 MHz to 10 MHz ± 0.03 dB ± 0.05 dB
10 MHz to 4.5 GHz ± 0.02 dB ± 0.08 dB
4.5 GHz to 6 GHz ± 0.02 dB ± 0.15 dB
Reflection tracking 100 kHz to 1 MHz ± 0.05 dB ± 0.40 dB
1 MHz to 10 MHz ± 0.03 dB ± 0.05 dB
10 MHz to 4.5 GHz ± 0.03 dB ± 0.06 dB
4.5 GHz to 6 GHz ± 0.03 dB ± 0.10 dB
Trace noise 10 MHz to 6 GHz
1kHz IF Bandwidth
0.003 dBrms / 0.02 degree rms (typ.)
Sweep Speed 10 MHz to 6 GHz,
201 points,
uncalibrated or one-port calibration
75 kHz IF Bandwidth 45 ms
10 kHz IF Bandwidth 61 ms
1 kHz IF Bandwidth 250 ms
10 MHz to 6 GHz,
201 points, two-port calibration
75 kHz IF Bandwidth 51 ms
10 kHz IF Bandwidth 85 ms
1 kHz IF Bandwidth 450 ms

Power

Range 100 kHz to 10 MHz -35 dBm to -4 dBm
10 MHz to 6 GHz -35 dBm to +5 dBm
Resolution 0.25 dB
Accuracy ± 1.5 dB

General

Input and output
RF Ports Port 1 and Port 2, N (F), impedance 50 Ω
Damage input level: +20 dBm or ±35 VDC
Power USB PD (65 W), supports power bank operation
USB Ports USB 3.0 Type-C *1, USB 2.0 Type-C *1, USB 2.0 Type-A *1
Ethernet Port RJ45, 1000 Mbps, supports remote control over LAN
Video and Audio Interfaces Micro HDMI * 1 (supports external display), 3.5 mm headphone jack *1
External Reference Clock Input MMCX (F), 10 MHz, allowable input level: -8 dBm to +10 dBm
External Trigger Input MMCX (F), 3.3 V CMOS, high impedance
Trigger Output MMCX (F), 3.3 V CMOS, high impedance
Display 10.1-inch IPS LCD, 1280 × 800, multi-touch
Power Consumption ≤ 15 W
Operating Time 5 hours (typ.)
Dimensions (L × W × H) 260 × 185 × 46 mm
Weight ≤ 1.4 kg
Operating Temperature (Ambient) 0 to 50 °C
Storage Temperature (Ambient) -20 to +70 °C
Operating relative humidity Ambient Temp.: 0 to 40°C 5 to 75%
Ambient Temp.: > 40°C 5 to 45%
Packaging accessories PNB-60 main unit *1, power adapter *1, power cord *1, ECB-60 electronic
calibration module *1, matched loads *2, USB cable *1,
CKB Series armored amplitude- and phase-stable cables *2,
SMA female-to-female adapter *1, wrench set *1

*Specifications apply under the following conditions:
(1) Dynamic range: IF bandwidth of 15 Hz, output power of +5 dBm; ambient temperature of 25 °C (± 3 °C), with a deviation from the calibration temperature of < 1 °C.
(2) Corrected system performance: IF bandwidth of 15 Hz; ambient temperature of 25 °C (± 3 °C), with a deviation from the calibration temperature of < 1 °C.
(3) Typical and nominal values are not guaranteed and do not include measurement uncertainty.
(4) Calibration includes SOLT and isolation calibration by default.
(5) Specifications are subject to change with hardware and software revisions without notice.